| Lantern |
- High-performance dual-condenser optics.
- Fully closed rotating iris cassette with protection.
- Manual shutter (dimmer) from 0 to 100%.
- Adjustable gobo holder, size "A" (Ø100).
- 6-color changer, pull-tab system, interchangeable filter holders.
- Frosted glass tilting (blurred).
- Inner slides for dichroic filter 120 x 120mm.
- Insulated manoeuvring handles.
- Compact volume, all captive parts.
- Reinforced steerable moving head.
- 230Volt auxiliary output for powering a ribbon color changer with its protection
|
| Alimentation |
- Silent self-adhesive ballast.
- Self tri voltage: 230V-50Hz, 245V-50Hz and 208V-60Hz.
- Bipolar circuit breaker protection.
- Mains presence indicator.
- Lamp Mounted Cord 3 m. Standard Harting 16x16A+T.
- 2.5m mains cord with CEE P17 32A plug.
- North American Use: 2 meter CSA/UL cable without plug.
- Comes with tool and maintenance parts case.
- Packaged in 2 flight cases
|
| Technical specifications |
- Nominal power consumption: 2500 Watts
- Operating voltage: European standard: 230/245 volts 50Hz
- Operating Voltage: North American Standard: 208 Volts 60Hz
- Minimum supply voltage: 198 Volts
- (Below this voltage = possible ignition fault).
- Voltage across the lamp: 115 Volts
- Amperage at lamp terminals: 25.6 Amps
- Lamp Brightness: 240,000 Lumens
- Luminous efficiency: 96 Lm/W
- Color temperature: 6000 Kelvin
- Base : G38
- Design life: 500 hours
|
| Precautions for use |
- The lifespan given by the manufacturer is a theoretical lifespan for so-called "laboratory" use based on a cycle of 3 hours on / 1 hour off, shorter cycles reduce the lifespan.
- In operating conditions, it is rare for a lamp to remain operational for more than 200 to 300 hours; its efficiency can decrease by up to 30%.
- Premature wear of the lamp, in show use, is mainly due to the frequency of priming. It is often better to keep a lamp on for an entire show than to turn on it repeatedly. (Each lighting reduces the life of the lamp by about 1 hour.)
- The projector equipment theoretically allows for a hot re-priming, but it is recommended to wait 10 minutes before re-priming. (This helps extend the life of the lamp.)
- Beyond 500 hours of use: change the lamp even if it is still shining.
|
| New lamp |
- In order to achieve a good ionization of the lamp, it is advised, at the first start-up, to let it run for a few hours in continuous operation.
- Keep the warranty card of the lamp safely, it will be asked of you in case of dispute.
|